Electric heating consumption through the year
A heater’s rated power is measured in kW. The electricity it uses over time is measured in kWh. Colder weather, higher thermostat settings and longer heating schedules can all increase that total.
Worked example · Monthly consumption · Smart meter evidence · Check your own use
From heater output to seasonal electricity use
Our German clay-core radiator worksheet uses a room of about 49 m³, an indoor temperature of 22°C and a cold-weather outdoor temperature of −8°C. With a heat-loss factor of 3, the worksheet estimates that the room needs 1.575 kW of heating output under those cold-weather conditions. That figure is a sizing result. You would select from the available radiator outputs when specifying the room. For the seasonal example, the diagram assumes an average demand of 28% of the calculated requirement across all hours of the heating period. That gives 0.441 kW on average, or 10.584 kWh per day.
The worksheet uses 220 days, which gives 2,328 kWh. The dates marked on the diagram, 1 October to 30 April inclusive, cover 212 days in a non-leap year and give 2,244 kWh. The worksheet does not explain how it derived 28%. Treat it as an illustration for this example. A room’s size, heat loss, thermostat settings and heating schedule can change the result substantially.
How the same seasonal total could vary by month
The table distributes the 2,244 kWh example using Scottish outdoor temperatures. It gives colder months a larger share. The Scottish temperatures come from Met Office 1991–2020 regional averages. The electricity figures are modelled for the example room.
Scottish example for one room. Each point shows a modelled monthly total. The shaded months fall outside the modelled heating season.
| Month | Approx. outdoor mean | Modelled heating electricity (kWh) |
|---|---|---|
| October | 8.2 °C | 224 |
| November | 5.2 °C | 305 |
| December | 3.1 °C | 381 |
| January | 2.9 °C | 385 |
| February | 3.1 °C | 343 |
| March | 4.4 °C | 340 |
| April | 6.5 °C | 266 |
| Season total | 2,244 | |
December to February account for about half of the example’s total. Actual use can vary within each month, and some homes need heating outside these dates.
How we calculated the monthly figures
We averaged the Met Office’s monthly mean daily maximum and minimum temperatures. Each month’s weight is its number of days multiplied by the difference between 15.5°C and that outdoor mean, with a minimum weight of zero. We then divided each month’s weight by the total weight and applied that share to 2,243.808 kWh. This approximates the shape of demand using the UK government’s 15.5°C heating degree-day base. The base is an outdoor modelling threshold. The worksheet’s 22°C is the indoor setpoint. Official degree days use daily temperatures, which capture warm and cold spells that monthly averages smooth out.
What smart meters show about the time of day
Figure 35 of the Smart Energy Research Lab report shows that households with electric storage radiators had a pronounced overnight electricity peak in 2023. Homes with electric radiators had a different daily profile. The study uses whole-home electricity readings, which include appliances and other loads. It gives useful evidence about when electricity is used, while the 28% assumption would need heater-level measurements to test.
How to check your own heating use
- Start with daily or half-hourly smart-meter readings from a mild week and a cold week. Record outdoor conditions, thermostat settings and when the rooms were heated.
- Use a dedicated circuit meter if you want to measure a fixed heater directly. Arrange this with an electrician. Whole-home readings include hot water, cooking and other appliances, so account for any changes in those loads.
- Multiply each period’s heating kWh by the unit rate that applied at the time. On Economy 7, calculate day and night charges separately. Include standing charges separately if comparing total bills.
For a worked tariff example, see Storage heaters vs clay-core radiators and infrared.
Sources
- Met Office climate averages, Scotland region, 1991–2020.
- DESNZ Energy Trends, UK weather, Table 7.1, and the UK energy balance methodology for the 15.5°C base.
- Smart Energy Research Lab, Energy use in GB domestic buildings 2022 and 2023, Figure 35.